This page is printable and fits in A4 paper : >>Page setup click here
Gas Transmitter Series 3000 XPIS
2 wire loop powered toxic and oxygen gas detector
for use in potentially explosive atmospheres
Gas Transmitter Series 3000 XPIS 

Series 3000 XPIS is supplied with all necessary accessories for easy installation, the universal bracket, M20 adaptor and weather proof cap
Connection & Power : 2-wire loop powered 17 Vdc to 24 Vdc
Current output : 0-100% FSD 4-20 mA
Relay :  Plug-in SurecellTM Electrochemical Sensor, intrinsically safe smart sensor
   

Classification

  • UL/c-UL Class I Div 1&2,
    Groups B, C & D -40°C to +55°C
  • UL/c-UL Class II Div 1&2,
    Groups E, F & G -40°C to +55°C
  • ATEX II 2G Ex d [ia] IIB+H2T4
    (Tamb -20°C to +55°C/ 4°F to 131°F)
    IECEx Ex d [ia] IIB+H2T4
Detectable Gas
Gas Selectable full scale range Default range
Oxygen 25.0% Vol only 25%Vol
Carbon Monoxide 100 to 1,000ppm 300ppm
Hydrogen Sulphide 10 to 50ppm 15ppm
Hydrogen Sulphide 50 to 500ppm 100ppm
Chlorine 5 to 20ppm 5ppm
Ozone 0 to 0.4ppm only 0.4ppm
Sulphur Dioxide

5.0 to 20.0ppm

15ppm
Chlorine Dioxide 0 to 1ppm only 1ppm
Nitrogen Monoxide 0 to 100ppm 100ppm
Nitrogen Dioxide 5 to 50ppm 10ppm
Hydrogen 0 to 1,000ppm only 1000ppm
Hydrogen 0 to 10,000ppm only 10000ppm
Hydrogen Chloride 10 to 20ppm 10ppm
Hydrogen Cyanide 0 to 20ppm only 20ppm
Hydrogen Fluoride 0 to 12ppm only 12ppm
Ammonia 50 to 200ppm 200ppm
Ammonia 200 to 1,000ppm 1000ppm
Phosphine 0 to 1.2ppm only 1.2ppm

Copyright 2007 Brave Engineering Ltd.127/13-14 Moo 12 Raminthra Rd., Klongkum, Bungkum, Bangkok 10230 Thailand.
Tel: +66(0)2944-4679, Fax: +66(0)2944-4920, Email: sales@braveengineering.com, Website: http://www.braveengineering.com