This page is printable and fits in A4 paper : >>Page setup click here
Searchpoint Optima Plus
Advanced infrared point gas detector
Searchpoint Optima Plus  

Gas Detector: Wide range of Hydrocarbon gases including solvent
Detection principle:  Dual wavelength infrared absorption (increase reliability with no moving part) with dynamic heating control ensures condensation free optic
Connection & Power:      3 wire sink or source  18-32 VDC (24 Vdc nominal)
Current Output: 

4-20 mA

    Classification
  • ATEX: BAS99ATEX2259X II 2GD EEx d IIC T100°C (Tamb -40°C to +55°C) T135°C (Tamb -40°C to +65°C)
  • UL/CSA Class 1, Div 1, groups B, C, and D
    (-40°C to +65°C) GOST and SAA

Searchline Excel
Open-path gas detector
Searchpoint Optima Plus
The world’s best selling infrared Open path gas detector

Detection principle: a patented double band pass pikes (fully commemorate for all types of fog and or rain)
Gas Detection: Methane, Ethane, Propane, Butane, Pentane, Ethylene, Propylene, Ethanol, Methanol Part
Length:     Short Range 5 m to 40 m (15 ft. to 130 ft.), Medium Range 40 m to 120 m (130 ft. to 390 ft.) Long Range 120 m to 200 m (390 ft. to 650 ft)
Current out put: 4-20 mA (source & sink available) and RS485
    Classification
  • ATEX: EExd IIC T5 (-40°C to +65°C) EExd IIC T6
    (-40°C to +40°C EX II 2G
  • UL: Class Div1 Groups B, C +D and Class 1 Zone 1 AEx d IIB + H2 (Tamb -40°C to 65°C)
  • CSA: Class 1 Div1 Groups B, C +D, T5 and Exd IIC T5
    (Tamb -40°C to 65°C)
  • FM: Class 1 Div 1 Groups B, C and D
  • Other: SAA, GOSST Independently assessed to IEC61508

Copyright 2007 Brave Engineering Ltd.127/13-14 Moo 12 Raminthra Rd., Klongkum, Bungkum, Bangkok 10230 Thailand.
Tel: +66(0)2944-4679, Fax: +66(0)2944-4920, Email: sales@braveengineering.com, Website: http://www.braveengineering.com