This page is printable and fits in A4 paper : >>Page setup click here
pH: Sugar Industry
POLILYTE HT, POLILYTE HTVP,
POLILYTE HTSK
POLILYTE PRO, POLILYTE PRO VP
POLILYTE PRO XP, POLILYTE RX
CHEMOTRODE P
 

pH: 0…14
0…130 °C
Max. 6 bar at 130 °C
Pt100 in HTVP and
HTSK version

  • It’s a POLISOLVE (pg. 9)!
  • Withstands continuous high process temperature
  • Proven design for sugar factories
  • Specially formed pH glass for excellent mechanical stability
  • Hamilton “H” pH glass provides stable readings
  • 2 SINGLE PORE's for direct sample contact with the POLISOLVE electrolyte. No Clogging!
  • Standard 12 mm shaft


pH: 0…14 or
Redox: +/- 2000 mV
-10…60 °C
Max. 6 or 50 bar at 60 °C
Pt1000 in VP-version

  • It’s a POLISOLVE (pg. 9)!
  • Suitable for process temperatures up to 60 °C
  • POLILYTE PRO XP pH sensors withstand continuous pressure of 50 bar !
  • POLILYTE PRO VP are equipped with a built-in Pt1000
  • POLILYTE RX is the redox sensor version of the same product family
  • SINGLE PORE for direct sample contact with the POLISOLVE electrolyte. No Clogging!

pH: 0...14
0…130 °C
Max. 6 bar
Refillable electrolyte

  • Long-term high temperature
    stable
  • Protelyte electrolyte, air pressurizable for a clog-free liquid junction
  • EVEREF-F reference cartridge prolongs electrode life in aggressive samples
  • 3 High Performance ceramic diaphragms for lower risk of blocking
  • Extremely long life in partially organic solutions and those containing proteins
pH: Swimming Pool, Sea and Ground Water
EASYCONTROL, EASYCONTROLORP
  
POLYPLAST PRO, POLYPLASTPRO RX,
POLYPLASTPRO SK
POLILYTE PRO, POLILYTE PRO VP,
POLILYTE PRO XP, POLILYTE RX

pH: 0…14 or
Redox: +/- 2000 mV
-10…60 °C
Max. 2 bar at 60 °C

  • Suitable for process temperatures up to 60 °C
  • EASYCONTROL is the pH sensor
  • EASYCONTROL ORP is the redox sensor version of the same product family
  • Ceramic diaphragm is the liquid junction.

pH: 0…14 or
Redox: +/- 2000 mV
-10…40 °C, briefly 60 °C
Max. 6 bar at 60 °C
Pt100 in SK-version

  • It’s a POLISOLVE (pg. 9)!
  • Suitable for slightly contaminated process samples
  • Robust plastic shaft with integrated pH membrane protection
  • POLYPLAST PRO SK are equipped with a built-in Pt100 and a SMEK connector head
  • POLYPLAST PRO RX is the redox sensor version of the same product family
  • SINGLE PORE for direct sample contact with the POLISOLVE electrolyte. No Clogging!

pH: 0…14 or
Redox: +/- 2000 mV
-10…60 °C
Max. 6 or 50 bar at 60 °C
Pt1000 in VP-version

  • It’s a POLISOLVE (pg. 9)!
  • Suitable for process temperatures up to 60 °C
  • POLILYTE PRO XP pH sensors withstand continuous pressure of 50 bar!
  • POLILYTE PRO VP are equipped with a built-in Pt1000
  • POLILYTE RX is the redox sensor version of the same product family
  • SINGLE PORE for direct sample contact with the POLISOLVE electrolyte. No Clogging!


Copyright 2007 Brave Engineering Ltd. 127/13 Moo 12 Raminthra Rd., Klongkum, Bungkum, Bangkok 10230 Thailand.
Tel: +66(0)2944-4679, Fax: +66(0)2944-4920, Email: sales@braveengineering.com, Website: http://www.braveengineering.com